5 aisg control tools, 1 aisg 2.0 reset – CommScope ATC300-2000 User Manual
Page 118
Section 11–Device Discovery and Addressing
ATC300-1000/2000 Teletilt
®
RET System
11-6
August 2014
Bulletin 639544 • Revision L
Figure 11-7. AISG Control Tools.
11.5 AISG Control Tools
The controller supports devices that utilize AISG 1.0, AISG 1.1, or AISG 2.0 protocols, or a mixed bus
of these devices.
AISG 2.0 Reset and Revert to AISG 1.1 control options are provided on the Bus Configuration screen.
These tools provide specific control capabilities for AISG 2.0 capable devices (Figure 11-7).
11.5.1 AISG 2.0 Reset
1. The AISG 2.0 Reset control broadcasts an AISG 2.0 Reset message to all devices on the bus.
This message will cause all AISG 2.0 devices to perform a reset.
2. Andrew AISG 1.0 and 1.1 devices are not affected by this message, with the exception of An
drew dual-mode devices, as explained below.
3. Andrew is unable to guarantee behavior for other manufacturer’s AISG 1.0 and 1.1 devices.
4. The AISG 2.0 Reset message triggers Andrew dual-mode capable devices that are currently op
erating in AISG 1.1 mode to reset and then begin operation in AISG 2.0 mode.
5. ATM200-002 and ATM200-A20 devices are dual-mode actuators. Earlier models of the ATM200-
002, with serial numbers that start with “C”, are not dual-mode capable.
6. ATC300 2.34_A and later will also trigger an Andrew AccuRET actuator currently operating in
AISG 1.1 to reset and begin operation in AISG 2.0 mode.
1. Click on AISG 2.0 Reset.
2. Click on
OK.
Revert to AISG 1.1