Section 22–

Adjusting Electrical Downtilt, Pan, Fan-Group SmartBeam

®

Antennas

ATC300-1000/2000 Teletilt

®

RET System

22-2

August 2014

Bulletin 639544 • Revision L

Figure 22-2. Adding Models To Be Included In The Sector Move.

Notice that the device that was selected to be included in the sector move is highlighted and displayed
in the Included box. This box displays a list of all devices that will be included in the sector move. Ini-
tially, this box contains only the antenna that was selected from the controller’s main interface screen.
The minimum, maximum, and current tilt for this device is displayed on this screen (Figure 22-2).

Other devices that have the same sector ID, minimum tilt, and maximum tilt, and are the same axis,
are listed in the Additional box. If desired, the configuration settings can be viewed for each device
before adding them to the sector group to be moved. Click on each model individually to view the
configurations for each device.

Note that up to 12 antenna/device pairs may be selected for a sector move. Any more than 12 will be
denied when attempting to add to the group for inclusion in the move.

3. Select the device, and click on Add (Figure 22-2). (Alternately, double-click on the device from

the Additional box to move the device to the Included box.)

4. Examine the group selected for the sector move (shown in the Included box), to ensure that the

group does not include any antennas that are not desired for this move. If you find that a device is
not wanted for inclusion in the sector move, click on the device, and click on Remove. (Alternately,
double-click on the device to remove it from the group.)

5. When satisfied with the list of antennas that will be included in the group move, enter a new downtilt

angle in the New Tilt text entry field, and click on Set Tilt to begin the move (Figure 22-3). Prog-
ress for each antenna movement in the group will be displayed separately (Figure 22-4). (Note
that these fields will have the appropriate labels for the axes selected.)

6. You will be notified when all antennas have successfully reached the new tilt angle. Click on Close

Window from the pop-up window (Figure 22-4).

7. The new angle will be displayed in the Current Tilt field and the New Tilt field will be cleared. If further

adjustments are needed, they may be done before exiting this screen. When the desired adjustments
are complete, click on Close (Figure 22-4) to return to the controller’s main interface screen (Figure
22-5).

2. Click on Add.

1. Click on the additional models, one at a time, to be included in the sector move.

(Double-clicking on the model will also add it to the group for the sector move.)