MacDon M155 Operators Manual User Manual
Page 96
Display (lower or upper line)
Description
##.# L FLOAT R ##.#
FLOAT SENS DISABLED
Left and right float setting (0.0–10.0).
Sensor Disabled.
LOAD|■■■■| | ####
Bar graph representing hydraulic operating pressure. Full
scale is pre-programmed overload pressure (2500–5000
psi). If sensor disabled, LOAD does not display
8
##.# VOLTS
Engine electrical system operating voltage.
SCROLL
SUB-MENU (lower line only)
#### KNIFE SPEED
##.# HEADER HEIGHT
LOAD|■■■■|■■■■|
##.## ##.# REEL IND
##.# ##.# DRAP INDX
Displays sub-menu after 2–3 seconds. Press SELECT to
cancel.
Scroll through sub-menu display with CDM switch.
##.## REEL MIN RPM (lower line)
Reel speed drops below programmed set-point.
MINIMUM (lower line)
Reel speed at zero ground speed.
Cab-Forward, Engine Running, Header Engaged, Rotary Header Installed
Scroll through display with cab display module (CDM) switch or ground speed lever (GSL) switch.
Display (lower or upper line)
Description
#####.# ENGINE HRS
Total engine operating time.
#####.# HEADER HRS
Total header operating time.
##.# ACRES/HOUR
##.# HECTARES/HOUR (If Metric)
Actual cutting rate in acres (hectares)/hour.
###.# SUB ACRES
###.# SUB HECTARES (If Metric)
Area cut since last reset. To reset, display SUB ACRES
on lower line, and hold down program switch until display
resets (5–7 seconds).
###### TOTAL ACRES
###### TOTAL HECT (If Metric)
Total area cut by machine.
#### DISC RPM
##.## DISC SENSOR
Disc rotational speed.
Sensor Disabled. RPM and SENSOR alternate at 1 second
intervals.
##.# HEADER HEIGHT
##.# HEIGHT SENSOR
Distance setting (00.0–10.0) between cutterbar and ground.
Sensor Disabled. HEIGHT and SENSOR alternate at
1 second intervals.
##.# HEADER ANGLE
##.# HEADER SENSOR
Angle setting (00.0–10.0) header relative to ground.
Sensor Disabled. ANGLE and SENSOR alternate at
1 second intervals.
##.# L FLOAT R ##.#
FLOAT SENS DISABLED
Left and right float setting (0.0–10.0).
Sensor Disabled.
8.
The LOAD sensor to monitor knife/conditioner circuit pressure is optional. To monitor reel/auger circuit pressure, relocate
sensor as per Form MD #169031, which is available through your Dealer.
169883
80
Revision A