MacDon M155 Operators Manual User Manual
Page 441
J1939
SPN
J1939
FMI
Lamp
Color
Cummins
Code
J1939
SPN
Cummins
Description
Category
CDM Error
Message
3
Amber
386
516
Sensor supply voltage #1
circuit - Voltage above
normal, or shorted to high
source
1079
4
Amber
352
516
Sensor supply voltage
#1 circuit - Voltage below
normal, or shorted to low
source
3
Amber
227
Sensor supply voltage #2
circuit - Voltage above
normal, or shorted to high
source
1080
4
Amber
187
5 Volts DC
Supply
Sensor supply voltage
#2 circuit - Voltage below
normal, or shorted to low
source
5 Volts DC
Supply
3
Amber
697
Sensor Circuit
- Voltage
ECM internal temperature
sensor circuit - Voltage
above normal, or shorted
to high source
1136
4
Amber
698
ECM internal temperature
sensor circuit - Voltage
below normal, or shorted
to low source
Sensor
Circuit -
Voltage
3
Amber
691
Turbocharger #1
compressor inlet
temperature sensor circuit
- Voltage above normal, or
shorted to high source
1172
4
Amber
692
Turbocharger
#1Compressor
Inlet
Temperature
Turbocharger #1
compressor inlet
temperature sensor circuit
- Voltage below normal, or
shorted to low source
Turbocharger
#1Compressor
Inlet
Temperature
5
Amber
177
Turbo wastegate drive
current below normal
6
Turbo wastegate drive
current above normal
1188
7
Turbo
Wastegate
Turbo wastegate not
responding
Turbo
Wastegate
169883
425
Revision A