beautypg.com

2closing platforms (standard position), 3opening platforms (major service position), Closing platforms (standard position) – MacDon M155 Operators Manual User Manual

Page 286: Opening platforms (major service position), 2 closing platforms (standard position), 3 opening platforms (major service position)

background image

MAINTENANCE AND SERVICING

5.5.2

Closing Platforms (Standard Position)

This procedure describes how to close the cab-forward left
platform (A). The same procedure is used to close the right
platform (B).

Figure 5.17: Platforms

1. If platform is latched in the open position, push latch (A)

to unlock it.

2. Grasp handle (B) on platform and push forward until it

stops and latch (A) engages.

Figure 5.18: Platform Latch

5.5.3

Opening Platforms (Major Service Position)

To improve access to the hydraulics plumbing or battery, the platforms can be swung away from the windrower.

1. Open the hood. Refer to

5.4.1 Opening Hood (Lower

Position), page 266

.

IMPORTANT:

Failure to open hood will result in damage to the
hood when the platform is moved.

169883

270

Revision A