beautypg.com

MacDon M155 Operators Manual User Manual

Page 350

background image

MAINTENANCE AND SERVICING

1. The battery main disconnect switch (A) is located on

the right-hand frame rail beside the batteries. Ensure
battery switch (A) is switched to POWER OFF position.

2. Open the right cab-forward platform to expose the

batteries. Refer to

5.5.1 Opening Platforms (Standard

Position), page 269

.

3. Remove cable ties securing battery cables to

battery clamp.

Figure 5.136: Battery Switch

4. Position new batteries (G) on dual battery support.

NOTE: Ensure that batteries are positioned so that the

positive posts (C) face aft.

5. Install strap (F) with bolts (E).

6. Rotate bar (B) into position and secure with bolt (A).

7. Connect battery cables. Refer to

Connecting Batteries,

page 335

.

8. Close the platform. Refer to

5.5.2 Closing Platforms

(Standard Position), page 270

.

Figure 5.137: Battery Location

169883

334

Revision A