MacDon M155 Operators Manual User Manual
Page 435
J1939
SPN
J1939
FMI
Lamp
Color
Cummins
Code
J1939
SPN
Cummins
Description
Category
CDM Error
Message
3
Amber
263
Fuel
Temperature
Engine fuel temperature
sensor 1 circuit - Voltage
above normal, or shorted
to high source
4
Amber
265
Engine fuel temperature
sensor 1 circuit - Voltage
below normal, or shorted
to low source
174
16
Amber
261
Engine fuel temperature
- Data valid but above
normal operational range
- Moderately severe level
Fuel
Temperature
0
Red
214
Engine oil temperature
- Data valid but above
normal operational range
- Most severe level
2
Amber
425
Engine oil temperature -
Data erratic, intermittent,
or incorrect
3
Amber
212
Engine oil temperature
sensor 1 circuit - Voltage
above normal, or shorted
to high source
175
4
Amber
213
Oil
Temperature
Engine oil temperature
sensor 1 circuit - Voltage
below normal, or shorted
to low source
Oil
Temperature
0
Red
234
Engine speed high - Data
valid but above normal
operational range - Most
severe level
2
Amber
689
Engine Speed
Primary engine speed
sensor error - Data erratic,
intermittent, or incorrect
8
141
141
Speed/Timing
Sensor
Abnormal signal frequency
190
15
N/A
141
Engine Speed
Engine overspeed -
Warning
Engine
Speed
251
2
Maint
319
Real Time
Clock Power
Real time clock power
interrupt - Data erratic,
intermittent, or incorrect
Real Time
Clock Power
169883
419
Revision A