OPERATION

Examples:

3. Windrower is operating at 8 mph with HEADER INDEX ON and set at -1.0.

Display shows 7.0 -1.0 REEL IND where 7.0 (8.0-1.0) is the reel speed in mph and -1.0 is the
HEADER INDEX setting.

4. Windrower speed drops to 7.5 mph at same HEADER INDEX setting.

Display shows 6.5 -1.0 REEL IND where 6.5 (7.5-1.0) is the reel speed in mph and -1.0 is the
HEADER INDEX setting.

5. Windrower is operating at 8 mph with HEADER INDEX ON and set at 2.0.

Display shows:

10.0 2.0 REEL IND

where 10.0 (8+2.0) is the reel speed in mph and 2.0 is the

HEADER INDEX setting.

Reel Only Speed

Figure 4.285: Operator Console

A - Display

B - Header Index

C - Reel Fast

D - Reel Slow

E - Display Selector

CAUTION

Check to be sure all bystanders have cleared the area.

Set the speed of the reel independently of ground speed as follows while operating the windrower:

NOTE:

This procedure is similar to changing the draper speed “on the go” with the conveyor speed control
switch. Refer to

Setting Draper Speed Independent of Ground Speed, page 235

. These changes

become the new set-points.

1. Set HEADER INDEX (B) to OFF.

169883

231

Revision A