Display (lower or upper line)
Description
##.# VOLTS
Engine electrical system operating voltage.
SCROLL
SUB-MENU (Lower Line Only)
#### KNIFE SPEED
##.# HEADER HEIGHT
LOAD|■■■■|■■■■| ####
Displays sub-menu after 2–3 Seconds. Press SELECT to
cancel. Scroll through sub-menu display with CDM switch.
Cab-Forward, Engine Running, Header Engaged, Draper Header, Index Switch OFF
Scroll through display with cab display module (CDM) switch or ground speed lever (GSL) switch.
Display (lower or upper line)
Description
#####.# ENGINE HRS
Total engine operating time.
#####.# HEADER HRS
Total header operating time.
##.# ACRES/HOUR
##.# HECTARES/HOUR (if metric)
Actual cutting rate in acres (hectares)/hour.
###.# SUB ACRES
###.# SUB HECTARES (if metric)
Area cut since last reset. To reset, display SUB ACRES
on lower line, and hold down program switch until display
resets (5–7 seconds).
###### TOTAL ACRES
###### TOTAL HECT (if metric)
Total area cut by machine.
##.## REEL MPH
##.## REEL KPH (if metric)
##.## REEL SENSOR (flashing)
Reel peripheral speed.
Sensor Disabled. MPH or KPH and SENSOR alternate
at 1 second intervals.
##.# DRAPER SPEED
Draper speed (0.0–11.0).
#### KNIFE SPEED
#### KNIFE SENSOR
Knife speed In strokes per minute.
Sensor Disabled. SPEED and SENSOR alternate at
1 second intervals.
##.# HEADER HEIGHT
##.# HEADER SENSOR
Distance setting (00.0–10.0) between cutterbar and ground.
Sensor Disabled. HEIGHT and SENSOR alternate at
1 second intervals.
##.# HEADER ANGLE
##.# HEADER SENSOR
Angle setting (00.0–10.0). Header relative to ground.
Sensor Disabled. ANGLE and SENSOR alternate at
1 second intervals.
##.# L FLOAT R ##.#
FLOAT SENS DISABLED
Left and right float setting (0.0–10.0).
Sensor Disabled.
### °C or F HYD OIL TEMP
### °C or F HYD SENSOR
Hydraulic oil temperature.
Sensor Disabled. TEMP and SENSOR alternate at
1 second intervals.
169883
78
Revision A