Drive PLC Developer Studio
Resources
8-12
l
DDS EN 2.3
8.4.3.3
Adding codes
Select Insert
WAdd new object to add a new code.
Note!
It is not permissible to create codes on system variables.
No codes can be created for REAL variables.
•
Open the dialog box
Enter the new object to select the variable to be linked to the code.
•
Selection of the variable and confirmation with OK will open the dialog box
Instance
Parameter Manager where the settings for a code can be made.
The Instance Parameter Manager supports the following data types.
•
BOOL
•
BYTE
•
SINT
•
USINT
•
INT
•
UINT
•
DINT
•
UDINT
•
WORD
•
DWORD
Note!
Copy and insert actions on objects will completely replace the contents.
8.4.3.4
Dialog box Instance Parameter Manager
Open the dialog box
Instance Parameter Manager to edit the settings for an existing or specify the
settings for a new code.
Note!
System variables must not be linked with write/read codes.
Code/ index
•
The code range from C3000 to C7999 is available. Code numbers are entered without the
leading ’C’.
•
Clicking the button First instance inserts the known parameter code in the input field Code.
The input fields Code max./Code min. and Int. max./Int. min. are greyed out.
•
Selecting an existing code will return an error message on clicking OK.