3 parameter monitor, Drive plc developer studio – Lenze DDS v2.3 User Manual
Page 196

Drive PLC Developer Studio
Resources
8-6
l
DDS EN 2.3
8.3
Parameter monitor
The parameter monitor is an object on tab Resources in the
Object Organizer
.
Use the parameter monitor to parameterize codes
online
on the PLC. Parameterizable codes include
codes created via the Parameter Manager and those of the selected PC (e. g. 9300 Servo PLC, Drive
PLC).
Tip!
No modified code values will be saved in the project after log-out!
To save changes to code values, choose one of the following options.
Open the
Object Organizer
and double-click the object Parameter monitor to open the parameter
monitor.
•
Save the changes in the parameter set of the PLC (C0003=1).
•
Save the changes in the project by entering the new values into the object Code initialization
values in the
Object Organizer
.
•
Save the changes using the software tool Global Drive Control (GDC).
On its left, the parameter monitor shows a menu tree with folders assigned with codes or further
subfolders.
•
Folders identified with a plus sign contain subfolders.
– Click on the plus sign to open the folder and to show the subordinate folders. A minus sign
now replaces the plus sign.
– Click on the minus sign to hide the subfolders.
•
Folders without a plus or minus sign do not contain subfolders, but codes.
– Selecting such a folder will display the codes assigned to the folder on the right-hand side.
– Read-only codes are shown in grey.
– Codes whose values have not been read from the PLC yet are shown in green.