Drive plc developer studio, Working with projects and objects – Lenze DDS v2.3 User Manual
Page 101

Drive PLC Developer Studio
Working with projects and objects
6-23
l
DDS EN 2.3
QSP
Trip/CINH
Warning
Event during
program processing
Response of the automation system
PLC stop, breakpoint
•
Fail QSP is activated
•
Code C168, subcode 1
Error entry: none
•
CINH is activated
•
Code C168, subcode 1
Error entry: none
•
Motor continues running
•
Code C168, subcode 1
Error entry: none
Task overflow
•
Fail QSP is activated
•
Code C168, subcode 1
Error entry: Task overflow
•
CINH is activated
•
Code C168, subcode 1
Error entry: Task overflow
•
Motor continues running
•
Code C168, subcode 1
Error entry: none
Drive PLC
Automation system without drive function
Note!
The configuration of the digital outputs
– remains unchanged with the extension modules.
– remains unchanged with the Drive PLC.
QSP
Trip/CINH
Warning
Event during
program processing
Response of the automation system
PLC stop, breakpoint
•
CINH is activated
•
Code C168, subcode 1
Error entry: none
•
Motor continues running
•
Code C168, subcode 1
Error entry: none
Task overflow
•
CINH is activated
•
Code C168, subcode 1
Error entry: Task overflow
•
Motor continues running
•
Code C168, subcode 1
Error entry: none