PN

07

4-

44

6-

P1

J

XTC/3 Operating Manual

6

Average Power = xx.x %

7

S Value = 0 to 9999

8

Q Value = 0 to 99

9

Begin Frequency = xxxxxxxx.x Hz

10

End Frequency = xxxxxxxx.x Hz

11

Xtal Life = xx % (0 - 99)

12

Normal Completion or

13

End On Time Power or

14

End In Stop from (Stop Reason). Stop Reasons are one of the following:

Keyboard

Xtal Fail

Max Power

Hand Controller

Communications

Digital Input

Power Loss

Rate Dev Fail

Crystal Switch Fail

NOTE: If the layer is the first one of a process, a preface Begin Process xxx

(xxx is the process number or name (XTC/3M only), if the name is
programmed.) is output. If the layer is the last one of the process, a
postscript End Process is output. The data log information is available via
the remote communications S19 command. See Remote Communication
status commands,

section 5.2.2.5 on page 5-29

or

section 5.3.5.5 on page

5-42

.

3.6.15 TCP/IP

The optional TCP/IP interface will provide all the commands available through the
standard RS232 interface. The interface uses a static address entered via XTC/3
front panel (see

section 4.4.3.1 on page 4-25

).

DHCP is not supported.