2 standard update film name (xtc/3m only) – INFICON XTC/3 Thin Film Deposition Controller Operating Manual User Manual
Page 132

5 - 20
PN
07
4-
44
6-
P1
J
XTC/3 Operating Manual
All General parameters (4 bytes per parameter)
All parameters for each film (4 bytes per parameter) (9 or 32 films based on
XTC/3S or XTC/3M)
All input definitions (9) (1 byte per input) (XTC/3M only)
All output definitions (20) (1 byte per output) (XTC/3M only)
All output types (20) (1 byte per output) (XTC/3M only)
All Film Names (null terminated) (32 films based on XTC/3M only)
List of parameters for Command ID 3 = (XTC/3M only)
Number of Bytes in Response (2 bytes)
Every process layer list for each process 1 through 50 (2 byte length (for the
number of layers programmed) followed by 1 byte for each programmed layer)
All process Names (null terminated) (1 - 50)
List of parameters for Command ID 4 = (XTC/3M only)
Number of Bytes in Response (2 bytes)
Every process layer list for each process 51 through 99 (2 byte length (for the
number of layers programmed) followed by 1 byte for each programmed layer)
All process Names (null terminated) (51 - 99)
5.2.2.4.2 Standard Update Film Name (XTC/3M only)
Command:
UN
Film Number =
values 20 to 7E inclusive, plus terminating null character)
Response:
None (Just header and trailer)