Details of the control connections
Terminal/
Name
Function
Data
Description / wiring suggestion
Parameter
44
24V
24V supply
(module, system bus level)
24VDC ±20%
≈ 50mA
protected against reverse
polarity
Connection for module supply
voltage and 24V source for the
digital inputs (DIN1 and DIN2)
-
40
GND/0V
Reference potential
for digital signals
-
C1
DIN1
Digital input 1
(I/O DeviceNet DIN1)
Low 0V ... 5V
High 15V ... 30V
R
i
= 8.1k
Input capacitance 10nF
Scan rate 1 ms
Each digital input has a reaction
time of 1ms
Inputs compliant with
EN 61131-2,
Type 1
P174
C2
DIN2
Digital input 2
(I/O DeviceNet DIN2)
P174
77
Sys H
System bus
data cable +
System bus
interface
-
78
Sys L
System bus
data cable -
-
40
GND/0V
Reference potential
for digital signals
-
Potential separation
45
VI /
24V BUS
24V bus supply
voltage
(Field bus)
For DeviceNet - Bus
24VDC ±20%
≈ 50mA, protected against
reverse polarity
DeviceNet bus supply is essential
-
75
CAN H
(incoming)
Bus +
DeviceNet H
RS485 transfer
technology
The use of a twisted, shielded two-
wire cable is strongly
recommended
-
76
CAN L
(incoming)
Bus -
DeviceNet L
-
46
GND/
0V BUS
Data ground
Bus reference potential
-
90
SHLD
Shield
Data cable shielding
-
45
VI /
24V BUS
24V bus supply
voltage
(Field bus)
For DeviceNet - Bus
24VDC ±20%
≈ 50mA, protected against
reverse polarity
DeviceNet bus supply is essential
-
75
CAN H
(outgoing)
Bus +
DeviceNet H
RS485 transfer
technology
The use of a twisted, shielded two-
wire cable is strongly
recommended
-
76
CAN L
(outgoing)
Bus -
DeviceNet L
-
46
GND/
0V BUS
Data ground
Bus reference potential
-