2 mains unit, sk tu4-24v-… (only sk 2x5e), 2 mains unit, sk tu4-24v, Only sk 2x5e) – NORD Drivesystems BU0200 User Manual
Page 104
3 Options
BU 0200 GB-4411
Subject to technical alterations
103
3.5.2
Mains unit, SK TU4-24V-
… (only SK 2x5E)
The mains unit is used to produce the 24V control voltage for SK 2x5E frequency inverters from the
available mains voltage (115V/230V/380V/500V). With this, a separate external 24V control voltage is not
necessary.
An analog output is also available for the connection of a potentiometer.
•
Mains unit for 100-240V, SK TU4-24V-123-B
•
Mains unit for 380-500V, SK TU4-24V-140-B
•
+24V- output voltage
•
1x analog input (e.g. potentiometer)
•
1x impulse output
•
Status LED = 24V
•
Max. permissible continuous current: 420mA
The Mains unit SK TU4-24V-
…can only be used in combination with an SK TI4-TU-NET adapter unit.
Details of the control connection are described in the Section for the Adapter Unit (Section 3.5.1.2)
A connection and parameterisation example is described in Section 3.4.1.
To process current setpoint values (0(4)-
20mA), the enclosed bag contains a 500Ω resistor, for connection
between terminals 12 and 14. Matching of the relevant input of the frequency inverter is made via parameter
(P420).
Setpoint
Parameter [Array]
Setting
0 … 20mA P420 [-02] or [-03] {26}
4 … 20mA P420 [-02] or [-03] {27}
NOTE
The use of SK CU4-24V-
… / SK TU4-24V-… on the SK 2x0E is not permissible!
A mains unit is integrated into the SK 2x0E inverter models, so that no external 24V DC is
required.