NORD Drivesystems BU0200 User Manual
Page 244
6 Parameterisation
BU 0200 GB-4411
Subject to technical alterations
243
Parameter
No. [Array]
Name
Factory
setting
Super
visor
Setting after commissioning
P 1
P 2
P 3
P 4
MOTOR DATA / CHARACTERISTIC CURVE PARAMETERS (Section 6.1.3)
P200 (P)
Motor list
0
P201 (P)
Nominal frequency [Hz]
50.0 *
S
P202 (P)
Nominal speed [rpm]
1385 *
S
P203 (P)
Nominal current [A]
4.8 *
S
P204 (P)
Nominal voltage [V]
230 *
S
P205 (P)
Nominal power [kW]
1.10 *
P206 (P)
cos phi
0.78 *
S
P207 (P)
Star Delta con.
[star=0/delta=1]
1 *
S
P208 (P)
Stator resistance [
]
6.28*
S
P209 (P)
No-load current [A]
3.0 *
S
P210 (P)
Static boost [%]
100
S
P211 (P)
Dynamic boost [%]
100
S
P212 (P)
Slip compensation [%]
100
S
P213 (P)
ISD control loop gain [%]
100
S
P214 (P)
Torque precontrol [%]
0
S
P215 (P)
Boost precontrol [%]
0
S
P216 (P)
Time boost precontrol [s]
0.0
S
P217 (P)
Oscillation damping [%]
10
S
P218
Modulation depth [%]
100
S
P219
Auto. magn. adjustment [%]
100
S
P220 (P)
Parameter identification
0
*) dependent on FI power or P200/P220
SPEED CONTROL (Section 6.1.4)
P300 (P)
Servo Mode [On / Off]
0
(Off)
S
P301
Incremental encoder
6
S
P310 (P)
Speed controller P [%]
100
S
P311 (P)
Speed controller I [%/ms]
20
S
P312 (P)
Torque current controller P [%]
200
S
P313 (P)
Torque current controller I
[%/ms]
125
S
P314 (P)
Torque current controller limit
[V]
400
S
P315 (P)
Field current controller P [%]
200
S
P316 (P)
Field current controller I [%/ms]
125
S
P317 (P)
Field current controller limit [V]
400
S
P318 (P)
Field weakening controller P
[%]
150
S