beautypg.com

NORD Drivesystems BU0200 User Manual

Page 245

background image

SK 200E Manual for frequency inverters

244

Subject to technical alterations

BU 0200 GB-4411

Parameter
No. [Array]

Name

Factory

setting

Super

visor

Setting after commissioning

P 1

P 2

P 3

P 4

P319 (P)

Field weakening controller I
[%/ms]

20

S

P320 (P)

Field weakening border [%]

100

S

P321 (P)

Speed control I brake off

0

S

P325

Function encoder

0

S

P326

Encoder ratio

1.00

S

P327 (P)

Speed slip error [rpm]

0

(Off)

S

P328 (P)

Speed slip delay [s]

0.0

S

CONTROL CLAMPS (Section 6.1.5)

P400 [-01] (P)

Function, setpoint inputs
Potentiometer 1

1

P400 [-02] (P)

Function, setpoint inputs
Potentiometer 2

15

P400 [-03] (P)

Function, setpoint inputs
Ext. analog input 1

0

P400 [-04] (P)

Function, setpoint inputs
Ext. analog input 2

0

P400 [-05] (P)

Setpoint input function
Setpoint module

1

P400 [-06] (P)

Function, setpoint inputs
Digital inpput 2

0

P400 [-07] (P)

Function, setpoint inputs
Digital inpput 3

1

P400 [-08] (P)

Function, setpoint inputs
Ext. analog input1 2nd IOE

0

P400 [-09] (P)

Function, setpoint inputs
Ext. analog input 2 2nd IOE

0

P401 [-01]

Analog input mode
Ext. analog input 1

0

P401 [-02]

Analog input mode
Ext. analog input 2

0

P401 [-03]

Function, analog input
Ext. analog input1 2nd IOE

0

P401 [-04]

Function, analog input
Ext. analog input 2 2nd IOE

0

P401 [-05]

Analog input mode
reserved

0

P401 [-05]

Analog input mode
reserved

0

P402 [-01]

Adjustment: 0% [V]
Ext. analog input 1

0.0

S

P402 [-02]

Adjustment: 0% [V]
Ext. analog input 2

0.0

S

P402 [-03]

Adjustment: 0% [V]
Ext. analog input 1 2nd IOE

0.0

S