NORD Drivesystems BU0200 User Manual
Page 231
SK 200E Manual for frequency inverters
230
Subject to technical alterations
BU 0200 GB-4411
Parameter
Setting value / Description / Note
Device
Supervisor
Parameter
set
P705
[-01]
...
[-05]
Dc.lnk volt. last er.
(Last link circuit voltage fault 1...5)
S
0 ... 1000 V DC
This parameter stores the link voltage that was being delivered at the time the error occurred.
The values of the last 5 errors are stored.
With the SimpleBox, the corresponding memory location 1...5- (Array parameter) must be
selected and confirmed using the OK key to read the stored error code.
P706
[-01]
...
[-05]
P set last error
(Parameter set, last error 1… 5)
S
0 ... 3
This parameter stores the parameter set code that was active when the error occurred. Data for
the previous 5 faults are stored.
With the SimpleBox, the corresponding memory location 1...5- (Array parameter) must be
selected and confirmed using the OK key to read the stored error code.
P707
[-01]
...
[-03]
Software-Version
(Software version/ revision)
0.0 ... 9999.9
This parameter shows the software and
revision numbers in the FI. This can be
significant when different FIs are assigned
the same settings.
Array [-03] provides information about any
special versions of the hardware or
software A zero stands for the standard
version.
[-01] = Software version, version number (V1.0)
[-02] = Software revision, revision number (R1)
[-03] = Special version, of the hardware/software
(0.0)
P708
State of digital in.
(Status of digital inputs)
00000 ... 11111
(bin)
or
00 ... 1F
(hex)
Displays the status of the digital inputs in binary/hexadecimal code. This display can be used to
check the input signals.
Bit 0 = Digital input 1
Bit 1 = Digital input 2
Bit 2 = Digital input 3
Bit 3 = Digital input 4
Bit 4 = PTC resistor input
Bit 5 - 7 reserved
First SK xU4-IOE (optional)
Bit 8 = 1st IO extension: Digital input 1
Bit 9 = 1st IO extension: Digital input 2
Bit 10 = 1st IO extension: Digital input 3
Bit 11 = 1st IO extension: Digital input 4
Second SK xU4-IOE (optional)
Bit 12 = 2nd IO extension: Digital input 1
Bit 13 = 2nd IO extension: Digital input 2
Bit 14 = 2nd IO extension: Digital input 3
Bit 15 = 2nd IO extension: Digital input 4
Bits 15-12 Bits 11-8
Bits 7-4
Bits 3-0
Minimum value
0000
0
0000
0
0000
0
0000
0
Binary
hex
Maximum value
1111
F
1111
F
1111
F
1111
F
Binary
hex
SimpleBox:
The binary Bits are converted into a hexadecimal value and displayed.
ParameterBox: The Bits are displayed with increasing values from right to left (binary).