2 Assembly and installation

BU 0200 GB-4411

Subject to technical alterations

49

Terminal/

Name

Function

{Factory setting}

Data

Description / wiring suggestion

Parameter

38

TF+

PTC resistor input

-

For monitoring motor temperature
with PTC

A shielded cable must be used for
separate mounting of the motor
and the FI (note cable length).

-

39

TF-

PTC resistor input

77

SYS H

System bus+

Up to four SK 2xxE can be
operated on one single
system bus.

Address = 32 / 34 / 36 / 38

Internal FI system bus for
communication with optional
modules and other frequency
inverters.

For further details see Section 9.7.

P509/510

P514/515

78

SYS L

System bus-


Additionally for SK 210E and SK 230E

89

VI /

24V SH

24V input for
'Safe Stop' funct

ion„

18…30V DC

at least 120-150mA

Fail-safe input

(For details, see supplementary
manual BU0230)

-

88

VI /

0V SH

Reference potential
for
'Safe Stop' function„

0V digital

Reference potential


Additionally for SK 220E and SK 230E

84

ASI+

Actuator/Sensor
Interface

Simple setting is
performed via DIP switch
S1:4 and 5 on the
SK 2xxE.

26.5

– 31.6V, max. 25mA

For control of the SK 2xxE via the
simple field bus level.

In this case, only the yellow AS
interface cable can be used.
Additional supply via he black
cable is not possible.

P480
... P483

85

ASI-

Terminal/

Name

Function

{Factory setting}

Data

Description / wiring suggestion

Parameter