NORD Drivesystems BU0200 User Manual
Page 263
SK 200E Manual for frequency inverters
262
Subject to technical alterations
BU 0200 GB-4411
Display in the
SimpleBox
Error
Text in the Parameter Box
Cause
Remedy
Group
Details in
P700[-01] /
P701
E008
8.0
Parameter lost
(EEPROM - Maximum value
exceeded)
Error in EEPROM data
Software version of the stored data set not compatible with
the software version of the FI.
NOTE:
Faulty parameters are automatically reloaded
(factory setting).
EMC interferences (see also E020)
8.1
Inverter ID error
EEPROM faulty
8.2
External EEPROM error
--
8.3
EEPROM KSE error
(Customer interface incorrectly
identified (customer‟s interface
equipment))
The upgrade level of the frequency inverter was not
correctly identified.
EEPROM with a firmware status of version 1.2 or above
plugged in to an FI with older firmware status
→ Loss of parameters! (See also note in Section 6)
Switch mains voltage off and on again.
8.4
EEPROM internal error
(Database version incorrect)
8.7
EEPROM copy differs
E009
---
reserved