4 optional locations for the "sk ti4, Adapter unit – NORD Drivesystems BU0200 User Manual
Page 27
SK 200E Manual for frequency inverters
26
Subject to technical alterations
BU 0200 GB-4411
2.1.4
Optional locations for the "SK TI4-
…" adapter unit
The above drawings indicate the different installation locations for optional modules. Option location 1 is
used for implementation of an internal bus module or an internal power supply (not SK 2x0E). An internal
brake resistor can be implemented at option location 2. External bus modules, 24 V power supplies (not
SK 2x0E) or potentiometer modules can be fitted at option location 3L or 3R. The same applies for external
braking resistors. Option locations 4 and 5 are for the mounting of M12 sockets or plugs. Locations 6, 7 and
8 for sizes 1 to 3 require an additional extension from M12 to M16 so that M12 sockets and connectors
(Section 2.8.4) can be fitted. For size 4 devices, the option locations 6 - 8 are also in M16. Only one option
per option location is possible. The preferred installation location for M12 sockets or connectors should be
4L or 4R. An additional M32 hole (option location 9) is provided for the mains connection of size 4.
4L
5L
3AL
3BL
6L
7L
8L
3L
3BR
3AR
8R
7R
6R
3R
4R
5R
2
1
Top view
View from right Size 1 to 3
View from left Size 1 to 3
View from right, Size 4
View from left, Size 4
3R
3BR
3AR
4R
5R
6R
7R
8R
9R
9L
3L
3AL
3BL
6L
7L
8L
4L
5L