NORD Drivesystems BU0200 User Manual
Page 232
6 Parameterisation
BU 0200 GB-4411
Subject to technical alterations
231
Parameter
Setting value / Description / Note
Device
Supervisor
Parameter
set
P709
[-01]
...
[-09]
Analog input voltage
(Voltage of analog inputs)
-100.0 ... 100.0 %
Displays the measured analog input value.
SK 2x0E*
SK2x5E**
[-01] = Analog input 1, function of analog
input 1 integrated into the FI
[-02] = Analog input 2, function of analog
input 2 integrated into the FI.
[-01] = Potentiometer 1, Internal potentiometer
P1 in the FI (Section 5.2.2), for setting
the maximum frequency, minimum
frequency and ramp time
[-02] = Potentiometer 2, as for potentiometer 1.
[-03] =
Ext. analog input 1, AIN 1 of the first I/O extension SK xU4-IOE
[-04] =
Ext. analog input 2, AIN 1 of the first I/O extension SK xU4-IOE
[-05] =
Setpoint module, in preparation
[-06] =
Analog function
2, analog function of the FI digital input 2
[-07] =
Analog function
3, analog function of the FI digital input 3
[-08] =
Ext. A.in 1 2nd IOE, "External analog input 1 2nd
IOE“,
AIN1 of the second I/O extension
(SK xU4-IOE) (= analog input 3).
[-09] =
Ext. A.in 2 2nd IOE, "External analog input 2 2nd IOE",
AIN2 of the second I/O extension
(SK xU4-IOE) (= analog input 4).
P710
[-01]
[-02]
Analog output volta.
(Analog output voltage)
0.0 ... 10.0 V
Displays the delivered value of analog output.
[-01] =
First IOE, AOUT of the first I/O extension (SK xU4-IOE)
[-02] =
Second IOE, AOUT of the second I/O extension (SK xU4-IOE)
P711
State of relays
(State of digital outputs)
00000 ... 11111
(bin)
or
00 ... FF
(hex)
Indicates the actual status of the digital outputs of the frequency inverter.
Bit 0 = Digital output 1
Bit 1 = mechanical brake
Bit 2 = Digital output 2
Bit 3 = reserved
Bit 4 = Digital output 1, IO extension 1
Bit 5 = Digital output 2, IO extension 1
Bit 6 = Digital output 1, IO extension 2
Bit 7 = Digital output 2, IO extension 2
Bits 7-4
Bits 3-0
Minimum value
0000
0
0000
0
Binary
hex
Maximum value
1111
F
1111
F
Binary
hex
SimpleBox: The binary bits are converted to a hexadecimal value and displayed.
ParameterBox: The bits are displayed with increasing values from right to left (binary).
P714
Operating time
(Operating time)
0.00 ... ___ h
This parameter shows the time for which the FI was connected to the mains and was ready for
operation.