2 details of the sk 2x0e control connections – NORD Drivesystems BU0200 User Manual
Page 49
SK 200E Manual for frequency inverters
48
Subject to technical alterations
BU 0200 GB-4411
2.8.2
Details of the SK 2x0E control connections
The frequency inverter generates its own control voltage and provides this to Terminal 43.
With size 4 the connection terminals for an electro-mechanical brake are located on a 2-pole terminal block
which is separate from the control terminal strip (Terminal 79/80, see Section 2.7.4).
Terminal/
Name
Function
{Factory setting}
Data
Description / wiring suggestion
Parameter
SK 200E, SK 210E, SK 220E, SK 230E
43
VO/24V
24V supply
Output
24VDC ±25%
max. 200mA (output)
Supply voltage provided by the
frequency inverter for connection to
the digital inputs or the supply of a
10-30V encoder.
-
40
GND/0V
Reference potential
for digital signals
-
21
DIN1
Digital input 1
{ON right}
Digital input as per
EN 61131-2 Type 1
Low: 0-5V
(~ 9.5k
Ω)
High: 15-30V
(~ 2.5-3.5k
Ω)
Input capacitance:
Input 1 + 4 = 10 nF
Input 2 + 3 = 1.2 nF
Scan time: 1ms
Reaction time:
≥ 4ms
HTL encoder connection
only to DIN2 and DIN3
possible
Frequency limits:
max. 205 kHz
min. 250 Hz
43
40
21
22
23
24
24V
GND / 0V
Inputs 1 + 4 react slowly
Inputs 2 + 3 react quickly
P420 [01]
22
DIN2
Digital input 2
{ON left}
P420 [02]
23
DIN3
Digital input 3
{fixed frequency 1,
(P465[-01])}
P420 [03]
24
DIN4
(only SK200/220E)
Digital input 4
{fixed frequency 2,
(P465 [-02])}
P420 [04]
1
DOUT1
Output 1
{Fault}
Digital output
24VDC, max. 20mA
max. 100k
load
For evaluation in a control system.
P434 [01]
3
DOUT2
Output 2
{Fault}
P434 [02]
14
AIN1+
(only SK200/210E)
Analog input 1
{Setpoint frequency}
U=0…10V, R
i
=30kΩ
Resolution 12Bit
I=0…20mA, Burden
resistor (250
Ω) via DIP
switch AIN1/2 (Diagnostic
opening D2, Section 4.1)
11
12
14
16
R=10k
Matching of the analog signals is
performed via P402 and P403.
P400 [01]
16
AIN2+
Analog input 2
{No function}
P400 [02]
12 AGND / 0V
Reference potential
for analogue signals
0V analog
only if SK 200E/SK 210E
present
Use Terminal 40 for
SK 220E/SK 230E
11
10V REF
+ 10V Reference
voltage
+10V, 5mA