NORD Drivesystems BU0200 User Manual
Page 80
3 Options
BU 0200 GB-4411
Subject to technical alterations
79
Connection plan and parameterisation of SK xU4-24V-
…, example
Frequency inverter
SK 205E-.../SK 215E-...
Co
ntro
l terminal b
ar
44
40
.
.
21
22
23
24
.
.
.
L1 - L2/N - L3
115/230/400V
24V mains unit
SK TU4-24V-...
(+ SK TI4-TU-NET)
*
or
SK CU4-24V-...
L1 - L2/N
115/230/400V
24V=
GND
10V=
AGND
0-10V
R
L
0-100%
1/3~ 115/230/400V + PE
Control terminal bar
44* 40 44* ... 11 14 12 B1
Switch
Potentiometer 10kOhm
AGND
0(2)-10V
Control terminal bar
44* 40 44* ... 11 14 12 B1
AGND
Control terminal bar
44* 40 44* ... 11 14 12 B1
Analog setpoint: 0(2) - 10V
Analog setpoint: 0 (4) - 20mA
500
Ω
=
0(4)-20mA
* with SK TU4-24V-
… : Terminal designation 43 instead of 44
DIP switch settings:
DIP3 = off, DIP4 = on, DIP5 = off (Section 5.2.2.2)
or
recommended
parameter setting, DIP1-8 = off:
P400 [07] = 1 P420 [02] = 2
P420 [01] = 1 P420 [03] = 26 (for 0-10V / 0-20mA signals)
= 27 (for 2-10V / 4-20mA signals)