NORD Drivesystems BU0200 User Manual
Page 258
6 Parameterisation
BU 0200 GB-4411
Subject to technical alterations
257
Step
Description
Comments
3
Connect the parameterisation adapter to the USB
port (USB 2.0 or higher) of the PC using the
enclosed cable.
4
Start NORD CON
5
Search for connected device
6
With an SK2xxE frequency inverter, the
parameterisation adapter, which is ready for
operation or the memory module are shown in
the device overview with status "ready for
switch-on".
6.1
To edit individual parameters:
Open the parameterisation window
(parameterise device)
6.2
To transfer a data set from a PC to the
Memory Module:
"Parameter download to device"
6.3
To transfer a data set from the memory
module to a PC:
"Parameter upload from device"
7
As with direct inverter parameterisation,
features such as database comparison or
printout of the parameter list are available.
8
Exit
NORD CON
and
disconnect
the
SK EPG-3H from the PC. The memory
module can now be removed from the
programming adapter for further use.
8.1
To edit several memory modules, it is not
necessary to exit NORD CON. However, the
serial interface must be disconnected in
NORD CON before the parameterisation
adapter is removed. Continue with step 5 after
reconnecting the parameterisation adapter.
1. Mark USS
2. Disconnect
the connection