6 Parameterisation
The frequency inverter, field bus and I/O -extension modules each have their own logic systems. These can
be adapted to customers' requirements by means of changeable parameters. The basic functions of the
particular modues are factory-set, so that the units have basic functionalities on delivery. Limited
adaptations of individual functions of the relevant devices can be implemented vie DIP switches. For all
further adjustments, access to the parameters of the relevant device with the aid of a ParameterBox
(SK PAR-3H, SK CSX-3H) or NORD CON software is essential. It should be noted that the hardware
configuration (DIP switches) has priority over configuration via software (parameterisation).
The following describes the relevant parameters for the frequency inverter (Section 6.1) and the I/O
extension modules (Section 6.2). Explanations for the parameters relating to the field bus options or the
special functions of the POSICON can be obtained from the relevant supplementary manuals.
ATTENTION
For changes to the frequency inverter software V 1.2 R0, the structure of individual
parameters has been changed for technical reasons.
(E.g.: up to version V 1.1 R2, (P417) was a simple parameter. As of version V 1.2. R0 this has been
divided into two arrays ((P417) [-01] and [-02]))
When plugging an EEPROM from a frequency inverter with an earlier software version into
a frequency inverter with a software version higher than V 1.2, the stored data is
automatically adapted to the new format. the new parameters are saved in the default
settings. Correct functioning is therefore ensured.
However, it is not permissible to plug an EEPROM with a software version higher
than V 1.2 into a frequency inverter with a lower software version, as this may lead to
a complete loss of data.