5 technical data for as interface – NORD Drivesystems BU0200 User Manual
Page 167
SK 200E Manual for frequency inverters
166
Subject to technical alterations
BU 0200 GB-4411
Method 1
With a normal addressing device (equipped with
an M12 plug for connection to the AS-i bus) the
AS-i can be integrated into the AS-i network via
a suitable access point. The prerequisite for this
is that the AS-i master can be switched off.
Method 2
With an addressing unit (equipped with an M12
plug for connection to the AS-i bus and an
additional M12 plug for an external power
supply), the addressing unit can be directly
connected into the AS-i cable.
NOTE
With the versions SK 220E and SK 230E a battery-operated addressing device is
sufficient.
5.4.5
Technical data for AS interface
Name
Value
SK 220E / SK230E
SK 225E / SK235E
Supply via AS interface connection,
PWR connection (yellow cable)
24V,
max. 25mA
26.5
– 31.6V,
max. 290mA
Slave profile
S-7.A
S -7.0
I/O-Code
7
7
ID Code
A
0
External ID Code 1 / 2
7
F
Address
1A
– 31A and 1B - 31B
(condition as delivered: 0A)
1
– 31
(condition as delivered: 0)
AS-I addressing unit
AS-i
MASTER
AS-i
Power
AS-i addressing unit