1 sk 2xxe control terminal versions – NORD Drivesystems BU0200 User Manual
Page 47
SK 200E Manual for frequency inverters
46
Subject to technical alterations
BU 0200 GB-4411
2.8.1
SK 2xxE control terminal versions
LABELLING, FUNCTION
SH:
"Safe stop" function„
ASI:
Integrated AS interface
24V:
24V power supply
AGND:
Reference potential for analogue
signals
GND:
Reference potential for digital
signals
DIN:
Digital input,
DOUT:
Digital output„
24V SH:
"Safe stop" input„
GND SH:
"Safe stop" reference potential„
SYS+/-:
System bus
MB+/-:
Electromagnetic brake control
(105V, 180V, 205V)
TF+/-:
Motor PTC connection
CONNECTIONS AND FUNCTIONS FOR SK 2XXE VERSIONS
DEPENDING ON CONFIGURATION LEVEL
Size 1 … 3
SK 200E
SK 210E SK 220E
SK 230E
FI type
SK 205E SK 215E SK 225E
SK 235E
(SH)
(ASI)
(SH+ASI)
Labelling
(SH)
(ASI)
(SH+ASI)
Pin
24V (internal, output max. 200mA)
43
1
44
24V, external 24V FI supply*
Analog input 1
ASI+, AS interface
14/84
2
44/84
24V, external 24V FI
supply
ASI+, AS interface
Analog input 2
16
3
40
GND, Reference potential for digital signals
AGND, Reference
potential for analog
signals
ASI-, AS interface
12/85
4
40/85
GND
ASI-, AS interface
DIN1 / digital input 1
21
5
21
DIN1 / digital input 1
DIN2 / digital input 2
22
6
22
DIN2 / digital input 2
DIN3, digital input 3
23
7
23
DIN3, digital input 3
DIN4,
digital
input 4
24V SH,
“Safe
stop”„
DIN4,
digital
input 4
24V SH,
“Safe
stop”„
24/89
8
24/89
DIN4,
digital
input 4
24V SH,
“Safe
stop”„
DIN4,
digital
input 4
24V SH,
“Safe
sto
p”„
GND
GND SH
GND
GND SH
40/88
9
40/88
GND
GND SH
GND
GND SH
DOUT1, digital output 1
1
10
1
DOUT1, digital output 1
GND
40
11
40
GND
SYS H, system bus +
77
12
77
SYS H, system bus +
SYS L, system bus -
78
13
78
SYS L, system bus -
10V Reference voltage
11
14
-
---
DOUT2, digital output 2
3
15
79
MB+, electromagnetic brake control
GND
40
16
80
MB-, electromagnetic brake control
TF+, motor PTC connection
38
17
38
TF+, motor PTC connection
TF-, motor PTC connection
39
18
39
TF-, motor PTC connection
*With the use of the AS interface, terminal 44 provides an output voltage (24V, max. 60mA). In this case, no voltage sources may be connected to this
terminal!
Detailed information regarding functional safety (Safe Stop) can be found in supplementary manual
BU0230.
–