8 Technical data

BU 0200 GB-4411

Subject to technical alterations

271

8.2 General data for mains/setpoint modules

Mains/setpoint modules (SK CU4/TU4-24V-..., SK TU4-POT-...)

Function

Specification

Analog setpoint input / PI input

0/2 ... 10V, 0/4 ... 20mA (if necessary with 500Ω burden), scalable

Analog setpoint resolution

10 bit based on measurement range

Analog output

0/2 ... 10V, 0/4 ... 20mA scalable

Setpoint consistency

Analog < 1%

Digital < 0.02%

Level of radio interference suppression B

Input voltage

1~ 100V -

10% … 240V +10% (SK xU4-…-123-B)

1~ 380V -

20% … 500V +10% (SK xU4-…-140-B)

Output voltage

24V DC ± 10%

Max. permissible continuous output
current

420 mA

Protective measures against

Short circuit

Overtemperature, overload

(limited monitoring)

Long-term storage

See Section 9.12.1