SK 200E Manual for frequency inverters
266
Subject to technical alterations
BU 0200 GB-4411
7.2.2
Table of possible error messages in the I/O extension module
Error number
Error
Text in the Parameter Box
Cause
Remedy
Group
Details in
P170
E1000
1000
EEPROM error
EMC interference on the SPI bus
Module faulty
1030
System bus, Bus Off
Check connections and cables
Ensure 24V power supply
Check Bus master.
E2000
2000
DIP changed/fault
DIP switch configuration changed during operation
2001
DIP invalid config
"DIP invalid configuration"
Illegal DIP switch setting
Check DIP switch setting. Note coding of analog inputs and
outputs!
2010
A out fault
"Analog output fault"
Check switching of 10V reference voltage
Short circuit of analog output
Analog output overload (max. 10mA)
Calibration error (P152)
A range error has occurred during measurement
of the correction values
The measured values could not be saved in the
EEPROM
2020
Inverter does not support
SK xU4-IOE
The connected frequency inverter does not support the
IO extension.
(Fault not associated with SK 2xxE possible)