NORD Drivesystems BU0200 User Manual
Page 299
SK 200E Manual for frequency inverters
298
Subject to technical alterations
BU 0200 GB-4411
I
Setpoint source and
setpoint selection
II
Signal processing
and ramp
III
Control and
motor model
(determination of slip)
9.11 Definition of setpoint and actual value processing (frequencies)
The frequencies used in parameters (P502) and (P543) are processed in various ways according the follow-
ing table.
Function
Name
Meaning
Output to ...
without
Right/Left
with
Slip
I
II
III
8
Setpoint frequency
Setpoint
frequency
from
setpoint source
X
1
Actual frequency
Setpoint frequency for motor
model
X
23
Actual
frequency
with slip
Actual frequency at motor
X
X
19
Setpoint frequency
master value
Setpoint frequency from
setpoint source
Master value
(free from enable correction)
X
X
20
Setpoint frequency
n R master value
Setpoint frequency from
motor model
Master value
(free from enable correction)
X
X
24
Master
value
of
actual
frequency
with slip
Actual frequency from motor
model
Master value
(free from enable correction)
X
X
X
21
Actual
frequency
without slip master
value
Actual frequency without slip
Master value
X