SK 200E Manual for frequency inverters

108

Subject to technical alterations

BU 0200 GB-4411

Terminal/

Name

Function

Data

Description / wiring suggestion

Parameter

21

GND

22

GND
Reference potential
for digital signals

As for terminal 15

Connection of supply voltage
for module and 24V source for
supply of the digital inputs
(DIN1 to DIN4)

-

23

24V

24

24V supply

(Module, system bus level)

As for terminal 11

-

25

DIN2

Digital input 2

(I/O IO extension DIN2)

Low 0V ... 5V
High 15V ... 30V

R

i

= 8.1k

Input capacitance 10nF

Scan rate 1ms,
Reaction time 1ms

The functions must be assigned in
parameter P480. The settings for
the first IOE are made in the arrays
[-05 / -07] and for the second IOE
in the arrays [-01, -03].
Inputs compliant with
EN 61131-2,

Type 1

P480
P174

26

DIN4

Digital input 4

(I/O IO extension DIN4)

P480
P174

27

GND

28

GND
Reference potential
for digital signals

As for terminal 15

Connection of supply voltage
for module and 24V source for
supply of the digital inputs
(DIN1 to DIN4)

-

29

24V

30

24V supply

(Module, system bus level)

As for terminal 11

-

Potential separation

31

24V 2

24V supply
of digital outputs

24VDC ±20%

Up to 1A, according to load
reverse polarity protected

Supply voltage connection for
digital outputs (DO1 and DO2)

If necessary, bridge to

24V

terminal

Recommendation: use an external
24V source

-

32

0V 2

GND 2
Reference potential
for digital outputs

Ground for digital outputs (DO1 and
DO2)

If necessary, bridge to

GND

terminal

-

33

DO1

Digital output 1

(I/O IO extension DO1)

Low = 0V
High: 24V

Rated current: 500mA
each

The functions must be assigned in
parameter P481. The settings for
the first IOE are made in the arrays
[-07 / -08] and for the second IOE
in the arrays [-05, -06].

Outputs compliant with
EN 61131-2

P481
P175

34

DO2

Digital output 2

(I/O IO extension DO2)

P481
P175

35

0V 2

36

GND 2
Reference potential
for digital outputs

Ground for digital outputs (DO1 and
DO2)

If necessary, bridge to

GND

terminal

-

3.5.4.2

Configuration

Configuration of the external I/O extension (SK TU4-IOE-

…) is carried out in the same way as for the

internal I/O - extension SK CU4-IOE. The relevant details are described in Section 3.4.3.2.