3 hand-held technology units for atex zone 22 3d, 4 braking resistors – NORD Drivesystems BU0200 User Manual

Page 63

background image

SK 200E Manual for frequency inverters

62

Subject to technical alterations

BU 0200 GB-4411

2.10.2.3 Hand-held Technology Units for ATEX Zone 22 3D

All hand-held technology units are not approved for continuous use in the ATEX Zone 22 3D. The may
therefore only be used during commissioning or for maintenance purposes, if it is ensured that
no explosive dust atmosphere exists.

Name

Part Number

Approved for
ATEX Zone 22 3D

Not approved for
ATEX Zone 22 3D

SK CSX-3H

275281013

x

SK PAR-3H

275281014

x

ATTENTION

The diagnostic opening of the basic unit for the connection of a hand-held
technology unit or a PC must not be opened in an atmosphere containing
explosive dust.

2.10.2.4 Braking resistors

External braking resistors of type SK BRE4-x-xxx-xxx are not permitted for use in the ATEX Zone 22 3D.

Name

Part Number

Approved for
ATEX Zone 22 3D

Not approved for
ATEX Zone 22 3D

SK BRI4-1-100-100

275272005

x

SK BRI4-1-200-100

275272008

x

SK BRI4-1-400-100

275272012

x

SK BRI4-2-100-200

275272105

x

SK BRI4-2-200-200

275272108

x

SK BRE4-1-100-100

275273005

x

SK BRE4-1-200-100

275273008

x

SK BRE4-1-400-100

275273012

x

SK BRE4-2-100-200

275273105

x

SK BRE4-2-200-200

275273108

x

ATTENTION

If an internal braking resistor of type SK BRI4-x-xxx-xxx is used, the power limitation for
this must be activated under all circumstances. This is usually done by setting DIP
switch 8 to "ON". Alternatively, parameters (P555), (P556) and (P557) can be
parameterised with the appropriate values. Only the resistors assigned to the relevant
inverter type may be used.