2 overview of external control devices – NORD Drivesystems BU0200 User Manual
Page 132
4 Display and control
BU 0200 GB-4411
Subject to technical alterations
131
4.2 Overview of external control devices
All parameters can be easily accessed for reading or editing by means of an optional SimpleBox or
ParameterBox. The changed parameter data are stored in the non-volatile EEPROM memory. This provides
the possibility of transferring a dataset from one FI to another by plugging in the EEPROM.
In addition, up to 5 complete frequency inverter data sets can be saved in the ParameterBox and then
recalled.
The connection between the SimpleBox or ParameterBox is made with an RJ12-RJ12 cable.
Module
Description
Data
SimpleBox
Hand-held
SK CSX-3H
Used (exclusively) for commissioning,
parameterisation, configuration and control
of the frequency inverter. Storage of the
parameters is not possible.
Manual BU 0040 (www.nord.com)
4-digit, 7-segment LED display
IP20
RJ12-RJ12 cable
(for connection to FI / Option)
Part No. 275281013
ParameterBox
Hand-held
SK PAR-3H
Used for commissioning, parameterisation,
configuration and control of the frequency
inverter and its options (SK xU4-
…). Saving
of parameters is possible.
Manual BU 0040 (www.nord.com)
4 digit back-lit LCD display, keyboard
Stores up to 5 complete FI data sets
IP20
RJ12-RJ12 cable (
for connection to FI / Option)
USB-Cable
(For connection to PC)
Part No. 275281014
Mounting the control unit on the SK 2xxE:
Installation of the control unit is performed as
follows:
1. Remove the protective caps from the RJ12
connectors.
2. Connect the RJ12-RJ12 cable between the
control unit and the frequency inverter.
3. During
normal
operation
after
commissioning, it is essential to replace the
protective caps and pay attention to sealing.
4. As long as one of the protective caps is
open, take care that no dirt or moisture
enters the device.