NORD Drivesystems BU0200 User Manual
Page 147
SK 200E Manual for frequency inverters
146
Subject to technical alterations
BU 0200 GB-4411
Display
Error
Cause
Remedy
209_1
INVERTER DOES NOT RESPOND
The ParameterBox is waiting for a response from the connected frequency
inverter. The waiting time has elapsed without a response being received.
Check the connection to the frequency inverter. The settings of the USS
parameters for the frequency inverter have been changed during
operation.
Identification errors
220
UNKNOWN DEVICE
Device ID not found. The connected inverter is not listed in the database of
the ParameterBox; no communication can be established.
ParameterBox is too old for the FI.
Please contact your Getriebebau Nord Representative.
221
SOFTWARE VERSION
NOT RECOGNISED
The software version was not found. The software of the connected
frequency inverter is not listed in the ParameterBox database, no
communication can be established.
Please contact your Getriebebau Nord Representative.
222
CONFIGURATION STAGE NOT
RECOGNISED
An unknown component has been detected in the frequency inverter
(Customer interface).
Please check the components installed in the frequency inverter
If necessary, check the software version of the ParameterBox and the
frequency inverter.
223
BUS CONFIGURATION HAS
CHANGED
After restoring the last Bus configuration, a device is reported that is different
from the one stored. This error can only occur if the parameter >Auto. Bus
Scan< is set to OFF and another device has been connected to the
ParameterBox.
Activate the Automatic Bus Scan function.
224
DEVICE NOT SUPPORTED
The inverter type entered in the ParameterBox is not supported!
The ParameterBox cannot be used with this inverter.
225
THE CONNECTION TO THE
INVERTER IS BLOCKED
Access to a device that is not online (previously Time Out error).
Carry out a bus scan via the parameter >Bus Scan< (P1001).
ParameterBox operating error
226
SOURCE AND TARGET ARE
DIFFERENT DEVICES
Copying objects of different types (from / to different inverters) is not
possible.
227
SOURCE IS EMPTY
Copying of data from a deleted (empty) storage medium
228
THIS COMBINATION IS NOT
PERMITTED
Target and source for the copying function are the same. The command
cannot be executed.
229
THE SELECTED ITEM IS EMPTY
Parameterisation attempt of a deleted storage medium
230
DIFFERENT SOFTWARE VERSIONS
Warning:
Copying objects with different software versions can cause problems when
transferring parameters.