SK 200E Manual for frequency inverters

154

Subject to technical alterations

BU 0200 GB-4411

5.2.2.4

Details of the potentiometers P1 and P2 (SK 2x0E S 4 and SK 2x5E)

The setpoint can be adjusted to a fixed value with the integrated potentiometer P1. Adjustment of the start-
up and braking ramps can be made via potentiometer P2.

Potentiometer

P1

(continuous)

P2

(stepped)

0% P102/103

P105

-

-

-

10%

0.2s

10Hz

1 P102/103

P104

20%

0.3s

20Hz

2

0.2s

2Hz

30%

0.5s

30Hz

3

0.3s

5Hz

40%

0.7s

40Hz

4

0.5s

10Hz

50%

1.0s

50Hz

5

0.7s

15Hz

60%

2.0s

60Hz

6

1.0s

20Hz

70%

3.0s

70Hz

7

2.0s

25Hz

80%

5.0s

80Hz

8

3.0s

30Hz

90%

7.0s

90Hz

9

5.0s

35Hz

100%

10.0s

100Hz

10

7.0s

40Hz

The function of P1 and P2 depends on DIP 4/5. The meaning
changes according to the setting.

As standard, P1 sets the setpoint value of 0-100% and P2 sets the
ramp from 0.2-7sec.

Potentiometer

P2


P1