3 electrical data 3~230v – NORD Drivesystems BU0200 User Manual
Page 276
8 Technical data
BU 0200 GB-4411
Subject to technical alterations
275
8.3.3
Electrical data 3~230V
Size 1
Device type:
SK 2xxE… -250-323-A
-370-323-A
-550-323-A
-750-323-A
-111-323-A
Nominal motor power
(4-pole standard motor)
230V
0.25 kW
0.37 kW
0.55 kW
0.75 kW
1.1 kW
240V
1
/
3
hp
½ hp
¾ hp
1 hp
1½ hp
In
p
u
t
Mains voltage
3~ 230V
3 AC 200 ... 240V,
10%, 47 ... 63 Hz
Typical input current
at 230V
3~ rms
1.4 A
1.9 A
2.6 A
3.5 A
5.1 A
3~ FLA
1.4 A
1.9 A
2.6 A
3.5 A
5.1 A
Rec. mains fuse
1 AC
slow-acting [A]
10 A
10 A
10 A
10 A
16 A
Permissible
mains fuses (UL)
RK5 or faster
fuses,
min 230V
5.0 A
5.0 A
10 A
10 A
10 A
Bussmann
FRS-R-5
FRS-R-5
FRS-R-10
FRS-R-10
FRS-R-10
Circuit breaker*
min. 230V
5.0 A
5.0 A
10 A
10 A
10 A
O
u
tp
u
t
Output voltage
3~ 230V
3 AC 0 - Mains voltage
Nominal output
current at 230V
rms
1.7 A
2.2 A
3.0 A
4.0 A
5.5 A
Motor
Assembly**
1.7A
(45°C)
2.2A
(45°C)
3.0A
(45°C)
4.0A
(45°C)
5.5A
(45°C)
Wall-mounted**
1.7A
(45°C)
2.2A
(45°C)
3.0A
(45°C)
4.0A
4.0A
Min. braking resistor
100
100
100
100
100
Recommended braking
resistor
Section 2.3
200
200
200
200
200
Motor-mounting (ventilated), or wall mounting with SK TIE4-WMK-L-1 (ventilated)
Max. continuous power / max. continuous current:
S1-50°C 0.25kW / 1.7A 0.37kW / 2.2A
0.55kW / 3.0A 0.75kW / 4.0A 1.10kW / 5.5A
Max. permissible ambient temp. with nominal output current
S1
S3
70%ED 10min
S6
70%ED 10min (100% / 20%Mn)
50°C
50°C
50°C
50°C
50°C
50°C
50°C
50°C
50°C
50°C
50°C
50°C
50°C
50°C
50°C
Wall mounting (unventilated)
Max. continuous power / max. continuous current:
S1-50°C
S1-40°C
S1-30°C
0.25kW / 1.7A
0.25kW / 1.7A
0.25kW / 1.7A
0.37kW / 2.2A
0.37kW / 2.2A
0.37kW / 2.2A
0.55kW / 2.8A
0.55kW / 3.0A
0.55kW / 3.0A
0.55kW / 2.8A
0.55kW / 3.5A
0.75kW / 4.0A
0.55kW / 3.4A
0.75kW / 4.2A
0.75kW / 4.8A
Max. permissible ambient temp. with nominal output current
S1
S3
70%ED 10min
S6
70%ED 10min (100% / 20%Mn)
50°C
50°C
50°C
50°C
50°C
50°C
48°C
50°C
50°C
32°C
40°C
35°C
20°C
30°C
25°C
* Circuit Breaker (inverse time trip type) as per UL489
** FLA (S1-40 °C)