357

A

pp
end

ix


(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

EAD

Boot error

A FPGA boot watchdog was detected. The core program may not be running
properly.

EAE

Application-update SCIF receive-queue overflow error

Excessive data is received from outside. (Confirm that a PC and IAI’s update
tool are used to update the application.)

EAF

Installed flash ROM type mismatch (Core)

The flash ROM type anticipated in the software does not match the flash ROM
type actually installed. Check the combination of software and hardware.

EB2

Flash busy reset timeout (Core detection)

Malfunction of the flash ROM. The busy status of the flash ROM is not reset.