(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

D81

Parameter error during calculation of valid target data

An invalid parameter value was detected during calculation of valid target data.
Check axis-specific parameter Nos. 7, 8, 138, etc.

D82

Simple interference check zone output-number specification error

A value other than an output port/global flag number (0 is allowed) may have
been input, or the specified number may be already used as a system output
number via the I/O parameter for output function selection.

D83

Simple interference check zone number error

The simple interference check zone number is invalid.

E01

DMA address error

DMA transfer error

E02

SCIF send-buffer overflow error

The SCIF send buffer overflowed.

E03

SCI send-buffer overflow error

The SCI send buffer overflowed.

E04

SCIF receive-buffer overflow error

The SCIF receive buffer overflowed. Excessive data was received from outside.

E05

SCI receive-buffer overflow error

The SCI receive buffer overflowed. Excessive data was received from the slave.

E06

Receive timeout error (Slave communication)

Response from the slave cannot be recognized.

E07

SCI overrun error (Slave communication)

Communication failure. Check for noise, circuit failure and slave card.

E08

SCI framing error (Slave communication)

Communication failure. Check for noise, shorting, circuit failure and slave card.

E09

SCI parity error (Slave communication)

Communication failure. Check for noise, shorting, circuit failure and slave card.

E0A

SCI CRC error (Slave communication)

The CRC in the message is invalid.

E10

SCIF communication mode error

The communication mode is invalid.

E11

SCI communication mode error

The communication mode is invalid.

E12

SIO-bridge SCIF send-queue overflow error

The send queue overflowed.

E13

SIO-bridge SCI send-queue overflow error

The send queue overflowed.

E14

SCI receive-data-register full wait timeout error

Communication failure. Check for noise, shorting, circuit failure and slave card.

E15

SCI overrun error

Communication failure. Check for noise, shorting, circuit failure and slave card.

E16

Program end confirmation timeout error

The program cannot be ended.

E17

I/O-processing-program start logic error

The I/O-processing-program start logic is invalid.

E18

Task ID error

The task ID is invalid.

E19

WAIT factor error

The WAIT factor is invalid.

E1A

WAIT logic error

The WAIT logic is invalid.

E1B

Point-data valid address error

Point-data valid address is not set.

E1C

Source data error

The source data is invalid.

E1D

Unaffected output number error

The unaffected output number is invalid. A value other than an output port
number (“0” is acceptable) may be input in I/O parameter Nos. 70 to 73.