IAI America XSEL-KX User Manual
Page 173
![background image](/manuals/350295/173/background.png)
157
Part 4 Commands
DFIF (Define coordinates of simple interference check zone)
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command, declaration
Output
(Output, flag)
Command,
declaration
Operand 1
Operand 2
Optional
Optional
DFIF
Interference
check zone
number
Position number
(Consecutive two
positions will be used)
CP
[Function] Set the consecutive two position data starting from the position number specified in operand
2 as the coordinate data defining the simple interference check zone specified in operand 1.
The position data specified in operand 2 will be set as definition coordinates 1 of the simple
interference check zone, while the next position data will be set as definition coordinates 2. If
the axis patterns of the consecutive two position data do not match, an "Error No. C30: Axis
pattern error" will generate.
(Note 1)
The definition coordinates of simple interference check zone are always treated as data on
the base coordinate system (load coordinate system No. 0). Therefore, to provide position
data for valid definition coordinates for the purpose of executing a DFIF command, the data
must be set on the base coordinate system beforehand.
(Note 2)
After the definition coordinates of simple interference check zone are changed, it will take 5
msec before the check result reflects the new settings.
(Note 3)
GRP commands are invalid with respect to this command.
[Example 1]
DFIF
1
170