IAI America XSEL-KX User Manual
Page 335
![background image](/manuals/350295/335/background.png)
319
Appendix
Other Parameters
No.
Parameter name
Default value
(Reference)
Input range
Unit
Remarks
38 PC/TP data protect
setting (Symbol,
parameter)
0H
0H ~
FFFFFFFFH
Bits 0 to 3:
Protect type (Parameter) (0:
Read/write, 1: Read only, 2: No
read/write)
Bits 4 to 7:
Protect release method (Parameter) (0:
Special operation)
Bits 8 to 11:
Protect type (Symbol) (0: Read/write,
1: Read only, 2: No read/write)
Bits 12 to 15: Protect release method (Symbol) (0:
Special operation)
* Referenced by the PC/TP (PC software version
2.0.0.42 or later and TP application version 1.09 or
later)
39 PC/TP data protect
setting (Coordinate
system)
0H
0H ~
FFFFFFFFH
Bits 0 to 3:
Protect type (Tool coordinate offset)
(0: Read/write, 1: Read only, 2: No
read/write)
Bits 4 to 7:
Protect release method (Tool
coordinate offset)
(0: Special operation)
Bits 8 to 11:
Protect type (Load coordinate offset)
(0: Read/write, 1: Read only, 2: No
read/write)
Bits 12 to 15: Protect release method (Load
coordinate offset)
(0: Special operation)
Bits 16 to 19: Protect type (Definition coordinates of
simple interference check zone)
(0: Read/write, 1: Read only, 2: No
read/write)
Bits 20 to 23: Protect release method (Definition
coordinates of simple interference
check zone)
(0: Special operation)
* Referenced by the PC/TP (PC software version
2.0.0.42 or later and TP application version 1.09 or
later)
40 For future extension
(Change prohibited)
3H
Reference only
For adjustment by the manufacturer
41 For future extension
(Change prohibited)
E0H
Reference only
For adjustment by the manufacturer
42 For future extension
(Change prohibited)
7H
Reference only
For adjustment by the manufacturer
43 Special monitor type
0H
Reference only
* Change is strictly prohibited unless instructed by the
manufacturer.
44 (For extension)
0
0H ~
FFFFFFFFH