103

Part 4 Commands


 FMIO (Set IN, INB, OUT, OUTB command format)

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command, declaration

Output

(Output, flag)

Command,
declaration

Operand 1

Operand 2

Optional

Optional

FMIO

Format

type

Prohibited

CP

[Function]

Set the data format for reading or writing I/O ports and flags with an IN, INB, OUT or OUTB
command.


(1) Operand 1 = 0 (Default status when a FMIO command has not been executed)

Data is read or written without being reversed.

(I/O, flag number upper)

(I/O, flag number lower)

01234567h

⇔ 01h 23h 45h 67h ⇔ 0000 0001 0010 0011 0100 0101 0110 0111

Variable 99

Temporary data

I/O port, flag status (0 = OFF, 1 = ON)

OUT(B) command

IN(B) command

(2) Operand 1 = 1

Data is read or written after its upper eight bits and lower eight bits are reversed every
16 bits.


(I/O, flag number upper)

(I/O, flag number lower)

01234567h

⇔ 23h 01h 67h 45h ⇔ 0010 0011 0000 0001 0110 0111 0100 0101

Variable 99

I/O port, flag status (0 = OFF, 1 = ON)


Temporary data

OUT(B) command

IN(B) command

(3) Operand 1 = 2

Data is read or written after its upper 16 bits and lower 16 bits are reversed every 32
bits.


(I/O, flag number upper)

(I/O, flag number lower)

01234567h

⇔ 45h 67h 01h 23h ⇔ 0100 0101 0110 0111 0000 0001 0010 0011

Variable 99

I/O port, flag status (0 = OFF, 1 = ON)



Temporary data

OUT(B) command

IN(B) command