beautypg.com

IAI America XSEL-KX User Manual

Page 175

background image




159

Part 4 Commands


 SEIF (Specify error type for simple interference check zone)

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command, declaration

Output

(Output, flag)

Command,
declaration

Operand 1

Operand 2

Optional

Optional

SEIF

Interference check

zone number

0 or 1 or 2

(Error type)

CP

[Function] Set the error type specified in operand 2 (see below) as the type of error generated upon

entry into the simple interference check zone specified in operand 1.

Type of error generated upon entry into the simple interference check zone

0: No error
1: Message level error
2: Operation-cancellation level error


[Example 1]

SEIF

1

2