Error list – IAI America XSEL-KX User Manual
Page 344

328
A
pp
end
ix
Error List (MAIN application) (In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
207
Update file name error (IAI protocol)
The update program file name selected in the update mode is invalid. Select the
correct file and repeat the update procedure from the beginning.
20E
Motorola S byte count error
The update program file is invalid. Check the file.
20F
Update target specification error (Received by the application)
An update target specification command was received by the application system.
To update the target, restart the controller and repeat the update procedure from
the beginning.
630
Update system code error (Detected by the application)
The update system code is invalid.
631
Update unit code error (Detected by the application)
The update unit code is invalid.
632
Update device number error (Detected by the application)
The update device number is invalid.
801
SCIF overrun status (IAI protocol reception)
Communication failure. Check for noise, connected equipment and
communication setting.
802
SCIF receive ER status (IAI protocol reception)
Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting. This error will also occur
when establishing communication with the PC/TP wrongly connected to SIO-CH1
being opened to the user.
803
Receive timeout status (IAI protocol reception)
The transfer interval after the first received byte is too long. Possible causes
include disconnected communication cable and error in the connected
equipment.
804
SCIF overrun status (SEL reception)
Communication failure. Check for noise, connected equipment and
communication setting.
805
SCIF receive ER status (SEL reception)
Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting.
806
SCIF receive ER status due to other factor (SEL reception)
Communication failure. Take the same action specified for error No. 804 or 805.
807
Drive-source cutoff relay ER status
The motor-drive power ON status remains ON even after the drive-source cutoff
processing was actuated. The drive-source cutoff relay contact may have melted.
808
Power OFF status during slave parameter write
The power was turned off while writing slave parameters. (This error can be
detected only when a backup battery is used.)
809
Power OFF status during data write to flash ROM
The power was turned off while writing data to the flash ROM. (This error can be
detected only when a backup battery is used.)
80A
Expanded-SIO overrun status (SEL reception)
Communication failure. Check for noise, connected equipment and
communication setting.
80B
Expanded-SIO parity ER status (SEL reception)
Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting.
80C
Expanded SIO framing ER status (SEL reception)
Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting.
80D
Expanded-SIO receive ER status due to other factor (SEL
reception)
Communication failure. Take the same action specified for error No. 80A, 80B or
80C.
80E
Expanded-SIO receive buffer overflow status (SEL reception)
The receive buffer overflowed. Excessive data was received from outside.
80F
Ethernet control status 1
Ethernet control information (for analysis)
810
Ethernet control status 2
Ethernet control information (for analysis)
811
Maintenance information 1
Maintenance information (for analysis)
812
Maintenance information 2
Maintenance information (for analysis)