9 task management – IAI America XSEL-KX User Manual
Page 125
![background image](/manuals/350295/125/background.png)
109
Part 4 Commands
1.9 Task Management
EXIT (End program)
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command, declaration
Output
(Output, flag)
Command,
declaration
Operand 1
Operand 2
Optional
Optional
EXIT
Prohibited Prohibited
CP
[Function]
End the program.
If the last step has been reached without encountering any EXIT command, the program will
return to the beginning.
(Note)
Status at program end
• Output ports
Retained
• Local flags
Cleared
• Local variables
Cleared
• Current values
Retained
• Global flags
Retained
• Global variables
Retained
[Example 1]
:
:
EXIT
End the program.
This manual is related to the following products: