(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

A5C

Copying-character count error warning with SCPY command

The specified number of copying characters is invalid.

A5D

SCIF open error in non-AUTO mode

The channel was opened in a non-AUTO mode. In the MANU mode, the PC/TP
connection must be forcibly disconnected before opening the serial channel
opened to the user. Exercise caution.

A5E

I/O-port/flag count specification error

The specified number of I/O ports/flags is invalid.

A5F

Fieldbus error (LERROR-ON)

A LERROR-ON was detected.

A60

Fieldbus error (LERROR-BLINK)

A LERROR-BLINK was detected.

A61

Fieldbus error (HERROR-ON)

A HERROR-ON was detected.

A62

Fieldbus error (HERROR-BLINK)

A HERROR-BLINK was detected.

A63

Fieldbus not ready

Fieldbus ready cannot be confirmed.

A64

SCIF overrun error (SIO bridge)

Communication failure. Check for noise, connected equipment and
communication setting.

A65

SCIF receive error (SIO bridge)

Communication failure. Check for noise, shorted/disconnected communication
cable, connected equipment and communication setting.

A66

SCI overrun error (SIO bridge)

Communication failure. Check for noise, circuit failure and slave card.

A67

SCI framing error (SIO bridge)

Communication failure. Check for noise, shorting, circuit failure and slave card.

A68

SCI parity error (SIO bridge)

Communication failure. Check for noise, shorting, circuit failure and slave card.

A69

Data change refusal error during operation

An attempt was made to change data whose change is prohibited during
operation (program is running, servo is in use, etc.).

A6A

Software reset refusal error during write

Software reset is prohibited while data is being written to the flash ROM or slave
parameters are being written.

A6B

Fieldbus error (FBRS link error)

A FBRS link error was detected.

A6C

PC/TP start command refusal error in AUTO mode

Starting from the PC software/TP connector is prohibited in the AUTO mode.

A6D

P0/P3/FROM-area direct write prohibition error

Direct write to the P0/P3/FROM areas is prohibited.

A6E

Refusal error during write

A processing not permitted while data is being written to the flash ROM or slave
parameters are being written was attempted.

A6F

Driver monitor type mismatch error

The support monitor type based on the Standard DIO Board Support Monitor
Type/Main CPU Board FROM Procedure does not match the monitor type set in
the PC software (monitor screen selection).