IAI America XSEL-KX User Manual
Page 195
![background image](/manuals/350295/195/background.png)
179
Part 4 Commands
TMLI (Move relatively between positions on tool coordinate system with interpolation)
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command, declaration
Output
(Output, flag)
Command,
declaration
Operand 1
Operand 2
Optional
Optional
TMLI
Position
number
Prohibited
PE
[Function] Each axis will move relatively on the tool coordinate system with interpolation (= CP
operation) based on the position data specified in operand 1 setting the travel amount from
the current position.
(Note 1)
Repeated use of incremental (relative) movement commands will accumulate coordinate-
conversion rounding errors.
[Example]
TMLI
120
Position data
Tool coordinate home
after movement
Tool coordinate home
before movement
Yt1
Yt1
-Yt1
30
60
-30
°
Xt1
Xt1