320
Appendix
Other Parameters
No.
Parameter name
Default value
(Reference)
Input range
Unit
Remarks
45 Special start
condition setting
0
0H ~
FFFFFFFFH
Bits 0 to 3: Enable start from PC/TP in AUTO mode =
Used exclusively by the manufacturer (0:
Do not enable, 1: Enable)
Bits 4 to 7: For future extension
Bits 8 to 11: Permission of auto program start when
all-operation-cancellation factor is present
(0: Do not permit, 1: Permit)
(Main application version 0.29 or later)
Bits 12 to 15: Permission of ON edge acceptance for
PIO program start (input port 000) when
all-operation-cancellation factor is
present
(0: Do not permit, 1: Permit)
* This parameter specifies an ON-edge
acceptance condition. If the starting
condition is not satisfied, an "Error No.
A1E: Start condition non-satisfaction
error" will generate.
(Main application version 0.29 or later)
46 Other setting bit
pattern 1
1
0H ~
FFFFFFFFH
Bits 0 to 3: Variable-value format type in response
message to real-number/variable query
(0: Big endian with four upper/lower
binary-converted bytes reversed, 1: Big
endian)
Bits 4 to 7: Decimal-place rounding selection for real-
number
→ integer-variable assignment in
LET/TRAN commands (Main application
version 0.24 or later) (0: Do not round, 1:
Round)
Bits 8 to 11: For future extension
Bits 12 to 15: Command processing selection when
subroutine step 1 input condition is not
specified at specification of TPCD
command “1”
(0: Do not execute, 1: Execute, 2:
Error)
(Main application version 0.31 or later)
47~
70
(For extension)
0