IAI America XSEL-KX User Manual
Page 241
225
Part 4 Commands
PDEC (Decrement palletizing position number by 1)
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command, declaration
Output
(Output, flag)
Command,
declaration
Operand 1
Operand 2
Optional
Optional
PDEC
Palletizing
number
Prohibited
CC
Decrement by 1 the palletizing position number for the palletizing number specified in operand 1.
If the decremented value is considered normal as a palletizing position calculated under the current
palletizing setting, the value will be updated. If not, the value will not be updated.
If the output field is specified, the output will turn ON when the value was successfully decremented, and
turn OFF if the decrement failed.
PSET (Set palletizing position number directly)
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command, declaration
Output
(Output, flag)
Command,
declaration
Operand 1
Operand 2
Optional
Optional
PSET
Palletizing
number
Data
CC
Set the value specified in operand 2 as the palletizing position number for the palletizing number
specified in operand 1.
If the specified value is considered normal as a palletizing position calculated under the current
palletizing setting, the value will be set. If not, the value will not be set.
If the output field is specified, the output will turn ON when the palletizing position number was
successfully updated, and will turn OFF if the update failed.